CLACK VALVES
YOU ARE HERE : HOME : VALVES | CLACK VALVES | WS1 CI SOFTENER / FILTER VALVE
clack WS1 CI SOFTENER / FILTER VALVE
CLACK WS1 CI WATER SOFTENER / FILTER VALVE
Solid state microprocessor with easy access front panel settings
Four methods to initiate regeneration; meter immediate, meter delayed, time clock delayed or pressure differential
Program in ppm, French degrees, German degrees, or cubic meters
Fully programmable regeneration cycle sequence (maximum 9)
Programmable regeneration cycle times
Days override feature; 1 – 28 days available
Backwash and brining ability to 21″ diameter tanks
Down-flow / up-flow regeneration
Stores system configuration and operation data in nonvolatile memory
Coin Cell Lithium battery back-up with a 24 hour carry over
Level VI 15-volt output DC power supply provides safe and easy installation
Control valve design provides optimum service and backwash rates
Pre or Post treated water regenerant refill
Mixing valve option available
Low salt alarm
24-hour clock
Patented one piece expanding seal spacer stack assembly U.S. Patent 6,402,944
Patented linearly reciprocating piston operation U.S. Patent 6,444,127
Reliable and proven DC drive
CLACK WS1CI | |
Ref | Description |
V1CIDTX-03 | WS1CI - Softener Valve, Time Clock 1” includes UK transformer |
V1CIDMX-03 | WS1CI - Softener Valve, Meter Controlled 1” includes UK transformer |
V1CIBTZ-03 | WS1CI Filter Valve, Time Clock 1” includes UK transformer |
CLACK WS1CI SPECIFICATIONS | |
Inlet/Outlet Fittings | 3/4" to 1.5” NPS |
Cycles | up to 9 |
Valve Material | Noryl (1) or equivalent |
Regeneration | downflow / upflow |
FLOW RATES | |
Service @ 15 psi/1 bar drop (includes bypass and meter) | 102 lpm (6.12 m3/h) (27 gpm) |
Backwash @ 25 psi/1.7 bar drop (includes bypass) | 102 lpm (6.12 m3/h) (27 gpm) |
OPERATING PRESSURES | |
Minimum / Maximum | 20 - 125 psi (1.4 - 8.6 bar) |
OPERATING TEMPERATURES | |
Minimum / Maximum | 40º - 110º F (4º – 43º C) |
METER | |
Accuracy | ± 5% |
Flow Rate Range | 0.95 - 102 lpm |
Volume Range | 0.02 - 5,700 m3 |
Totalizer | 1 m3 - 99,999 m3 |
DIMENSIONS & WEIGHT | |
Distributor Pilot | 1.050” OD Pipe (3/4" NPS) |
Drain Line | 3/4” or 1” NPT |
Brine Line | 3/8” or 1/2” OD Poly Tube |
Supply Voltage | 200VAC to 240VAC |
Supply Frequency | 50/60 Hz |
Output Voltage | 15VDC |
Output Current | 500 mA |
TANK APPLICATIONS | |
Water Softener | 6” – 21” diameter |
Water Filter (2) | 6” – 21” diameter |
CYCLES OF OPERATION (SOFTENER DOWNFLOW) | |
Cycle | Range of times minutes |
Backwash 1st (upflow) | 3 - 12 |
Regenerate Draw/Slow Rinse (downflow) | 50 - 70 |
Backwash 2nd (upflow) | 3 - 12 |
Fast Rinse (downflow) | 3 - 8 |
Regenerant Refill (in service with treated water) | As Programmed |
Service (downflow) | |
Mounting Base | 2 1/2” - 8 NPSM |
Height From Top Of Tank | 7 3/8” (187 mm) |
Weight | 4.5 lbs (2 kg) |
ELECTRICAL SPECIFICATIONS | |
Supply Voltage | 200VAC to 240VAC |
Supply Frequency | 50/60 Hz |
Output Voltage | 15VDC |
Output Current | 500 mA |
TANK APPLICATIONS | |
Water Softener | 6” – 21” diameter |
Water Filter (2) | 6” – 21” diameter |
CYCLES OF OPERATION (SOFTENER DOWNFLOW) | |
Choose up to nine regeneration cycles, in any order, with a wide range of available values: | |
Cycle | Range of times minutes |
Backwash | 1 - 120 minutes |
Rinse | 1 - 120 minutes |
Pause (service) | 1 - 480 minutes |
Brine (co-current) | 1 - 180 minutes |
Brine (counter-current) | 1 - 180 minutes |
Refill (softener) | 0.05 - 90.00 Kg |
Refill (filter) | 0.2 - 76.00 Liters |
Options: Backwash Filter, Bypass, Weather Cover
Compatible with the following typical concentration of regenerants or chemicals: Sodium chloride, potassium chloride, potassium permanganate, sodium bisulfite, chlorine and chloramines
1. Noryl is a trademark of Sabic Innovative Plastics IP B.V. Company 2. Filter tank size calculated @ 10 gpm of backwash per square foot of bed area