CLACK VALVES

YOU ARE HERE : HOME : VALVES | CLACK VALVES | WS1.5 CI SOFTENER / FILTER VALVE

clack WS1.5 CI SOFTENER / filter VALVE

Clack WS1 CI Softener / Filter Valve

CLACK WS1.5 CI WATER SOFTENER/ FILTER VALVE

1.5″ top mount control valve suited for mid-size commercial / industrial applications
Epoxy coated lead free brass valve body*
Economical stainless steel optional meter assembly
Service flow rate of 265 lpm (15.9 m3/h) (70 gpm), backwash 197 lpm (11.8 m3/h) (52 gpm)
Solid state microprocessor with easy access front panel settings
Front panel display for time of day, days until next regeneration, volume remaining and current flow rate
Four methods to initiate the downflow regeneration; meter immediate, meter delayed, time clock delayed or pressure differential
Program in ppm, French degrees, German degrees, or cubic meters
Fully programmable regeneration cycle sequence (maximum 9)
Programmable regeneration cycle times
Days override feature; 1-28 days available
Level VI 15-volt output DC power supply provides safe and easy installation
Pre or Post treated water regenerant refill
Low salt alarm
24 hour clock
Coin Cell Lithium battery back-up with a 24 hour carry over
Patented one piece expanding seal spacer stack assembly U.S. Patent 6,402,944
Patented linearly reciprocating piston operation U.S. Patent 6,444,127
Reliable and proven DC drive

Clack WS1.5 CI
RefDescription
V15CIDTX-05WS1.5 - Softener Valve, Time Controlled 1.5” includes UK transformer
V15CIDMX-05WS1.5 - Softener Valve, Meter Controlled 1.5” includes UK transformer
V15CIBTZ-05 WS1.5 - Filter Valve, Time Controlled 1.5” includes UK transformer
CLACK WS1.5 CI SPECIFICATIONS
Inlet/Outlet (1)1.5” Female BSPT or NPT
Cyclesup to 9
Valve MaterialLead free brass
Regenerationdownflow
CONTROL VALVE FLOW RATES
Service @ 1 bar/15 psi drop (includes meter)265 lpm (15.9 m3/h) (70 gpm)
Backwash @ 1.7 bar/25 psi drop197 lpm (11.8 m3/h) (52 gpm)
OPERATING PRESSURES
Minimum / Maximum20 - 125 psi (1.4 - 8.6 bar)
OPERATING TEMPERATURES
Minimum / Maximum4º- 43 ºC (40ºC - 110ºF)
METER
Accuracy± 5%
Flow Rate Range2 - 284 lpm (0.5 - 75 gpm)
Volume Range0.02 - 5,700 m3
Totalizer1 – 99,999 m3 (264 - 26,417,000 gallons
DIMENSIONS & WEIGHT
Distributor Pilot
Valve bodies with 1.5" Female BSPT Inlet & Outlet50 mm OD
Valve bodies with 1.5" Female NPT Inlet & Outlet1.90” OD (1.5" NPS)
Drain Line Connection (2)1.25” Female NPT
Adapter Included3⁄4" Male NPT Elbow
Brine Line Connection3⁄4” Female NPT
Adapter Included1⁄2” OD Poly Tube Compression
Mounting Base4" - 8 UN
Height From Top Of Tank191 mm (7.5”)
Shipping Weight With Meter9.5 kg (21 lbs.)
ELECTRICAL SPECIFICATIONS
Supply Voltage200VAC to 240VAC
Supply Frequency50/60 Hz
Output Voltage15VDC
Output Current500 mA
TANK APPLICATIONS
Water Softener12” - 30" Diameter (4)
Water Filter (3)12” - 30" Diameter
CYCLES OF OPERATION
Choose up to nine regeneration cycles, in any order, with a wide range of available values:
CycleRange of times minutes
Backwash1 - 120 minutes
Rinse1 - 120 minutes
Pause (service)1 - 480 minutes
Brine (co-current)1 - 180 minutes
Refill (softener)0.05 - 90.00 Kg
Refill (filter)0.2 - 76.00 Liters

1. See Distributor Pilot. 2. Casting comes with a 1.25″ Female NPT drain connection. An adapter is provided to accept existing WS1 drain line 3⁄4″ Male NPT flow controls up to 38 lpm (10 gpm). Other drain line flow controls are available for flow rates above 38 lpm (10 gpm).

3. Filter tank size calculated @ 407 lpm per m2 of bed area/10 gpm of backwash per square foot of bed area 4. Requires a V3158-02 installed for a brine elbow on the control valve, use of a 454 controlled flow brine valve assembly H7070-36CF-5 or H7070-54CF-5 (designed with 5 gpm BLFC) , 1” air check, or 494 brine valve assembly, and minimum 3⁄4” hard pipe PVC brine line.