CLACK VALVES

YOU ARE HERE : HOME : VALVES | CLACK VALVES | WS1.25 SOFTENER / FILTER VALVE

clack WS1.25 CI SOFTENER / filter VALVE

Clack WS1.25 CI Water Softener / Filter Valve

CLACK WS1.25 CI WATER SOFTENER/ FILTER VALVE

Solid state microprocessor with easy access front panel settings
Four methods to initiate regeneration; meter immediate, meter delayed, time clock delayed or pressure differential
Program in ppm, French degrees, German degrees, or cubic meters
Fully programmable regeneration cycle sequence (maximum 9)
Programmable regeneration cycle times
Days override feature; 1 – 28 days available
Backwash and brining ability to 21″ diameter tanks
Downflow regeneration
Stores system configuration and operation data in nonvolatile memory
Coin Cell Lithium battery back-up with a 24 hour carry over
Level VI 15-volt output DC power supply provides safe and easy installation
Patented one piece expanding seal spacer stack assembly U.S. Patent 6,402,944
Patented linearly reciprocating piston operation U.S. Patent 6,444,127
Control valve design provides optimum service and backwash rates
Pre or Post treated water regenerant refill
Mixing valve option available
Low salt alarm
24-hour clock
Reliable and proven DC drive

Clack WS1.25 CI
RefDescription
V125CIDMX-03WS1.25 CI - Softener Valve, Meter Controlled 1.25” includes UK transformer
V125CIBTZ-03WS1.25 CI Filter Valve, Time Clock 1.25” includes UK transformer
CLACK WS1.25 SPECIFICATIONS
Inlet/Outlet Fittings3/4" to 1.5” NPS
Cyclesup to 9
Valve MaterialNoryl (1) or equivalent
Regenerationdownflow / upflow
FLOW RATES
Service @ 15 psi/1 bar drop (includes bypass and meter)129 lpm (7.7 m3/h) (34 gpm)
Backwash @ 25 psi/1.7 bar drop (includes bypass)121 lpm (7.3 m3/h) (32 gpm) (2)
OPERATING PRESSURES
Minimum / Maximum20 - 125 psi (1.4 - 8.6 bar)
OPERATING TEMPERATURES
Minimum / Maximum40º - 110º F (4º – 43º C)
METER
Accuracy ± 5%
Flow Rate Range0.95 - 129 lpm
Volume Range0.02 - 5,700 m3
Totalizer1 m3 - 99,999 m3
DIMENSIONS & WEIGHT
Distributor Pilot1.32" OD Pipe (1" NPS) or 32 mm OD
Brine Line3/8” or 1/2” OD Poly Tube
Mounting Base2 1/2” - 8 NPSM
Height From Top Of Tank16 lbs (7.25 kg)
ELECTRICAL SPECIFICATIONS
Supply Voltage200VAC to 240VAC
Supply Frequency50/60 Hz
Output Voltage15VDC
Output Current500 mA
TANK APPLICATIONS
Water Softener6” – 21” diameter
Water Filter (2)6” – 21” diameter
CYCLES OF OPERATION (SOFTENER DOWNFLOW
Choose up to nine regeneration cycles, in any order, with a wide range of available values:
CycleRange of times minutes
Backwash1 - 120 minutes
Rinse1 - 120 minutes
Pause (service)1 - 480 minutes
Brine (co-current)1 - 180 minutes
Brine (counter-current)1 - 180 minutes
Refill (softener)0.05 - 90.00 Kg
Refill (filter)0.2 - 76.00 Liters
Height From Top Of Tank7 3/8” (187 mm)
Weight4.5 lbs (2 kg)
ELECTRICAL SPECIFICATIONS
Supply Voltage200VAC to 240VAC
Supply Frequency50/60 Hz
Output Voltage15VDC
Output Current500 mA
TANK APPLICATIONS
Water Softener6” – 21” diameter
Water Filter (2)6” – 24” diameter
CYCLES OF OPERATION (SOFTENER DOWNFLOW)
Choose up to nine regeneration cycles, in any order, with a wide range of available values:
CycleRange of times minutes
Backwash1 - 120 minutes
Rinse1 - 120 minutes
Pause (service)1 - 480 minutes
Brine (co-current)1 - 180 minutes
Refill (softener)0.05 - 90.00 Kg
Refill (filter)0.2 - 76.00 Liters

Options: Backwash Filter, Bypass, Weather Cover
Compatible with the following typical concentration of regenerants or chemicals: Sodium chloride, potassium chloride, potassium permanganate, sodium bisulfite, chlorine and chloramines