CLACK VALVES

YOU ARE HERE : HOME : VALVES | CLACK VALVES | WS1 TC SOFTENER / FILTER VALVE

clack WS1 TC SOFTENER / FILTER VALVE

Clack WS1 TC Softener FIlter Valve

CLACK WS1 TC WATER SOFTENER / FILTER VALVE

More informative 4 digit LCD Display with Status Indicators
Solid state microprocessor with easy access front panel settings
Service flow rate of 27 gpm, backwash 27 gpm
Front panel display for time of day, days until next regeneration
Days between regeneration: 1–99 days standard; 7-day optional
Double backwash feature offers optimum regeneration, cleaning ability and efficiency
10 selectable pre-programmed regeneration cycles
Coin Cell Lithium battery back-up with an 8 hour carry over
Post treated water regenerant refill
Reliable and proven DC drive
Backwash and brining ability to 21” diameter tanks
Auto detection of 50/60 Hz line frequency, with automatic 12/24 hour time keeping formats

CLACK WS1TC
RefDescription
VWS1TCSWS1TC - Softener Valve, Time Clock 1” includes UK transformer
VWS1TCFWS1TC - Filter Valve, Time Clock 1” includes UK transformer
CLACK WS1TC SPECIFICATIONS
Inlet/Outlet Fittings3/4" to 1.5” NPS
Cyclesup to 6
Valve MaterialNoryl (1) or equivalent
FLOW RATES
Service @15 psi drop (includes bypass)27 gpm
Backwash @ 25 psi drop (includes bypass)27 gpm
Cv Service7.0
Cv Backwash5.4
OPERATING PRESSURES
Minimum / Maximum20 psi – 125 psi
OPERATING TEMPERATURES
Minimum / Maximum40. – 110. F
DIMENSIONS & WEIGHT
Distributor Pilot1.050” OD Pipe (3/4" NPS)
Drain Line3/4” or 1” NPT
Brine Line3/8” or 1/2” OD Poly Tube
Mounting Base2 1/2” - 8 NPSM
Height From Top Of Tank7 3/8”
Weight4.5 lbs
ELECTRICAL SPECIFICATIONS
Supply Voltage200VAC to 240VAC
Supply Frequency50/60 Hz
Output Voltage15VDC
Output Current500 mA
TANK APPLICATIONS
Water Softener6” – 21” diameter
Water Filter (2)6” – 21” diameter
CYCLES OF OPERATION (SOFTENER DOWNFLOW)
CycleRange of times minutes
Backwash 1st (upflow)3 - 12
Regenerate Draw/Slow Rinse (downflow)50 - 70
Backwash 2nd (upflow)3 - 12
Fast Rinse (downflow)3 - 8
Regenerant Refill (in service with treated water)As Programmed
Service (downflow)

Options: Backwash Filter, Bypass, Weather Cover
Compatible with the following typical concentration of regenerants or chemicals: Sodium chloride, potassium chloride, potassium permanganate, sodium bisulfite, chlorine and chloramines

1. Noryl is a trademark of Sabic Innovative Plastics IP B.V. Company 2. Filter tank size calculated @ 10 gpm of backwash per square foot of bed area