Softcontrol Data Water Hardness Monitoring

Softcontrol Clack is the “guardian” for a CLACK water softener, reducing operating costs by up to 60%.

The continuous maintenance of water softening systems can be reduced to a necessary level.

The regeneration is automatically triggered on the CLACK control head when the configured limit value is exceeded.

The quality and throughput of soft water per column is constantly analysed and displayed on the control panel.

Operating data such as flow rate, number of regenerations and other data are electronically recorded and chronologically and stored in the device.

The savings achieved are shown for each softener column. Optionally, the monitoring can be extended to the brine / salt storage tank.

Softcontrol Clack can be installed on any water softener with sodium chloride regeneration and CLACK control heads (type TWIN; WS 1.0; WS 1.5; WS 2.0 or WS 3.0).

 

SOFTCONTROL CLACK TECHNICAL DATA
Wall Mounted400 x 250 x 160 mm (W x H x D)
WeightApprox 8 kg
Surrounding Temperature5 °C … 50 °C
Relative Humidity20 % … 80 %
Power Supply100 … 240 Volt / 50 … 60 Hz
Power Consumption15 V DC, about 20 Watt
Raw and Blended Water ConnectionBranch pipe with connection for PA-tube o.d. 4 mm, i.d. 2 mm, up streamed dirt filter ≤ 0,1 mm recommended
Raw and Blended Water PressureMinimum 1 bar up to maximum 10 bars
DrainMinimum ø 15 mm, pressure free
Quality of Raw and Soft WaterNatural water, free of grease, oil and brine germ content < 5000 CFU/ml
Hardness Range Raw Water0.72 mmol/l ... 32.4 mmol/l
Possibility of Calibration Input Actual Value of Blended Water Hardness0.2 mmol/l ... 10,8 mmol/l
Setting of Threshold Value0.2 mmol/l ... 10,8 mmol/l
Sensor ControlAutomatic
External SignalingPotential-free contacts (sensor alarm, threshold value alarm) 4 … 20 mA current loop, paramterisable